Feature 
Cisco ASA 5505; Security Plus 
Cisco ASA 5512-X; Security Plus 
Cisco ASA 5515-X 
Shock 
1.14 m/sec (45 in./sec) 1/2 sine input 
70G, 4.22 m/sec 
70G, 4.22 m/sec 
Vibration 
0.41 Grms2 (3 to 500 Hz) random input  0.41 Grms2 (3 to 500 Hz) random 
input 
0.41 Grms2 (3 to 500 Hz) random 
input 
Acoustic noise 
60 dBa max 
64.2 dBa max 
64.2 dBa max 
Temperature 
-13 to 158ºF (-25 to 70ºC) 
-13 to 158ºF (-25 to 70ºC) 
-13 to 158ºF (-25 to 70ºC) 
Relative humidity 
5 to 95 percent noncondensing 
10 to 90 percent noncondensing 
10 to 90 percent noncondensing 
Altitude 
0 to 15,000 ft (4570m) 
Designed and tested for 0 to 15,000 
ft (4570m) 
Designed and tested for 0 to 
15,000 ft (4570m) 
Shock 
30G 
70G, 4.22 m/sec 
70G, 4.22 m/sec 
Vibration 
0.41 Grms2 (3 to 500 Hz) random input  1.12 Grms2 (3 to 500 Hz) random 
input 
1.12 Grms2 (3 to 500 Hz) random 
input 
AC range line voltage 
100 to 240 VAC 
100 to 240 VAC 
100 to 240 VAC 
AC normal line voltage 
100 to 240 VAC 
100 to 240 VAC 
100 to 240 VAC 
AC current 
1.8A 
4.85A 
4.85A 
AC frequency 
50/60 Hz 
50/60 Hz  
50/60 Hz 
Dual-power supplies 
None 
None 
None 
DC domestic line voltage 
-40.5 to 56 VDC (-48 VDC nominal) 
-40.5 to 56 VDC (-48 VDC nominal) 
DC international line 
voltage 
-55 to -72 VDC 
(-60 VDC nominal) 
-55 to -72 VDC 
(-60 VDC nominal) 
DC current 
15A (maximum input) 
15A (maximum input) 
Steady state 
20W 
51W 
65W 
Maximum peak 
96W 
56W 
70W 
Maximum heat 
dissipation 
72 BTU/hr 
192 BTU/hr 
239 BTU/hr 
Form factor 
Desktop 
1RU, 19-in. rack-mountable 
1RU, 19-in. rack-mountable 
Dimensions (H x W x D) 
1.75 x 7.89 x 6.87 in. (4.45 x 20.04 x 
17.45 cm) 
1.67 x 16.7 x 15.6 In (4.24 x 42.9 x 
39.5 cm) 
1.67 x 16.7 x 15.6 In (4.24 x 42.9 x 
39.5 cm) 
Weight (with AC power 
supply) 
4.0 lb (1.8 kg) 
13.39 lb (6.07 kg) 
13.39 lb (6.07 kg) 
Safety 
UL 60950, CSA C22.2 No. 60950, EN 
60950 IEC 60950, AS/NZS60950 
IEC 60950-1: 2005, 2
nd
 Edition 
EN 60950-1:2006+A11: 2009 
UL 60950-1:2007, 2
nd
 Edition;  
CSA C22.2 No. 60950-1-07, 2
nd
 
Edition 
IEC 60950-1: 2005, 2
nd
 Edition 
EN 60950-1:2006+A11: 2009 
UL 60950-1:2007, 2
nd
 Edition;  
CSA C22.2 No. 60950-1-07, 2
nd
 
Edition 
Electromagnetic 
compatibility (EMC) 
CE marking, FCC Part 15 Class B, 
AS/NZS CISPR22 Class B, VCCI 
Class B, EN55022 Class B, CISPR22 
Class B, EN61000-3-2, 
EN61000-3-3 
CE: EN55022 2006+A1: 2007 Class 
A; EN55024 
1998+A1:2001+A2:2003; EN61000-
3-2 2009; EN61000-3-3 2008; 
FCC: CFR 47, Part 15 Subpart B 
Class A 2010, ANSI C63.4 2009; 
ICES-003 ISSUE 4 
FEBRUARY.2004; 
VCCI: V-3/2011.04; 
C-TICK: AS/NZS CISPR 22,2009 
KC: KN22 & KN24 
CE: EN55022 2006+A1: 2007 
Class A; EN55024 1998+A1: 
2001+A2:2003; EN61000-3-2 
2009; EN61000-3-3 2008; 
FCC: CFR 47, Part 15 Subpart B 
Class A 2010, ANSI C63.4 2009; 
ICES-003 ISSUE 4 
FEBRUARY.2004; 
VCCI: V-3/2011.04; 
C-TICK: AS/NZS CISPR 22,2009 
KC: KN22 & KN24 
Industry certifications 
FIPS 140-2 Level 2 
In process: Common Criteria EAL4+ 
US DoD Application-Level Firewall for 
Medium-Robustness Environments, 
and Common Criteria EAL4 for 
IPsec/SSL VPN 
In process 
In process 
1
 Maximum throughput measured with UDP traffic under ideal conditions. 
2
 Multiprotocol = Traffic profile consisting primarily of TCP-based protocols/applications like HTTP, SMTP, FTP, IMAPv4, 
BitTorrent, and DNS.