Set System Time
Set System Time 
For logging purposes and other time-sensitive tasks (such as SSL certificate generation), the time on the 
Clean Access Manager and Clean Access Servers needs to be correctly synchronized. The System Time 
tab lets you set the time on the Clean Access Manager and modify the time zone setting for the Clean 
Access Manager operating system. 
After CAM and CAS installation, you should synchronize the time on the CAM and CAS before 
regenerating a temporary certificate on which a Certificate Signing Request (CSR) will be based. The 
easiest way to ensure this is to automatically synchronize time with the time server (Sync Current Time 
button).
Note
The time set on the CAS must fall within the creation date/expiry date range set on the CAM’s SSL 
certificate. The time set on the user machine must fall within the creation date /expiry date range set on 
the CAS’s SSL certificate. 
The time can be modified on the CAS under Device Management > CCA Servers > Manage [CAS_IP] 
> Misc > Time
. See the Cisco NAC Appliance - Clean Access Server Installation and Administration 
Guide 
for details. 
To view the current time:
1.
Go to Administration > CCA Manager > System Time.
2.
The system time for the Clean Access Manager appears in the Current Time field.
Figure 15-3
Time Form
There are two ways to adjust the system time: manually, by typing in the new time, or automatically, by 
synchronizing from an external time server. 
To manually modify the system time: 
1.
In the System Time form, either: 
2.
Type the time in the Date & Time field and click Update Current Time. The time should be in the 
form: 
mm/dd/yy hh:ss PM/AM
3.
Or, click the Sync Current Time button to have the time updated by the time servers listed in the 
Time Servers field.