supported on this interface
Error Message
ETHPORT-5-IF_DOWN_INITIALIZING: Interface [chars] is down (Initializing)
Explanation The interface is in the process of coming up
Recommended Action If the interface is stuck in this state for a while, check the output of
'show port internal event-history' to determine what it is waiting for
Error Message
ETHPORT-5-IF_DOWN_INTERFACE_REMOVED: Interface [chars] is down (Interface
removed)
Explanation Interface removed
Recommended Action No action is required.
Error Message
ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface [chars] is down (Link failure)
Explanation The physical link has gone down
Recommended Action Ensure that the cable is connected and the remote end is not shut
down
Error Message
ETHPORT-5-IF_DOWN_LOOPBACK_DIAG_FAILURE: Interface [chars] is down (Diag
failure)
Explanation Diag failed on the interface
Recommended Action Collect more information about failed interface using command
'attach module' to connect to module
Error Message
ETHPORT-5-IF_DOWN_LOOPBACK_ISOLATION: Interface [chars] is down (Isolation due
to port loopback to same switch)
Explanation The interface is looped back to another interface on the same switch
Recommended Action Check the connectivity of this interface and ensure that it is
connected to another switch
Error Message
ETHPORT-5-IF_DOWN_MODULE_REMOVED: Interface [chars] is down (module removed)