Cisco Cisco Nexus 9000v Switch Release Notes

Page of 30
 
Cisco Nexus 9000 Series NX-OS Release Notes, Release 7.0(3)I2(4) 
Caveats 
 
15 
Record Number 
Description 
Show tech dme or dme logs will indicate following log messages on active sup as well as standby. 
[aaa] [DBG4] [] Failed to send ICMP Request (101) for sys/userext/tacacsext/tacacsplusprovider-x.x.x.x 
Where x.x.x.x is the ip address of the tacacs or radius server. 
An N3K running nxos.7.0 has an IPv6 BGP session to a directly connected peer on a port-channel sub-
interface. The peer addresses are link local addresses. The port-channel sub-interfaces have the same 
IPv6 link local address configured. If the link local address on an unrelated interface is changed a TCP 
reset gets sent for the IPv6 BGP session. Shut/no shut on the BGP interface is needed to recover. 
N9500 is a Border Leaf and learns prefix 172.21.26.0/24 via BGP in vrf from a firewall outside the 
fabric, and learns a default route from EVPN fabric in the same vrf from another Border Leaf. 
N0-DC1L-BLV-ZF-SV100# bcm-shell module 1 "l3 defip show" | grep 0.0.0.0 
2304  3           0.0.0.0/0            00:00:00:00:00:00 100018    0     0     0    0 n <<< 
3072  Global   0.0.0.0/0            00:00:00:00:00:00 149149    0     0     0    0 y 
When 9500 received packet from L3Vni destined to 172.21.26.0/24, it incorrectly forwards the packet 
using the default route programmed in VRF, instead of sending it to the fabric module that causes the 
packet to go into a loop. 
By default, the VSH daemon has console and vty exec-timeout turned off. 
The objects of type macAddress are shown as long ascii strings, instead of 6 byte hexa decimal values 
of the MAC address. 
LC would reset due to sysmgr resetting vntagc due to missing hearbeats. The following errors could 
appear in show logging nvram: 
VDC-1 %$ %SYSMGR-SLOT7-2-SERVICE_CRASHED: Service "vntagc" (PID 2816) hasn't caught signal 6 
(core will be saved). 
VDC-1 %$ %MODULE-2-MOD_DIAG_FAIL: Module 7 reported failure due to Service on linecard had a 
hap-reset in device DEV_SYSMGR (device error 0x402) 
VDC-1 %$ %PLATFORM-2-MOD_DETECT: Module 7 detected Module-Type 48x1/10G SFP+ 4x40G 
Ethernet Module Model N9K-X9564PX 
VDC-1 %$ %PLATFORM-2-MOD_PWRUP: Module 7 powered up 
Change HA policy of vntagc from reset to statuful. The vntagc crashes and related modules reset 
which cause route reconvergence again and packet loss.