Introduction
This document describes the interoperability problem seen with Hewlett−Packard (HP) Pass−Thru modules
and Cisco Nexus 5000 Series switches and also provides a solution to the problem.
Problem
There is a problem encountered after the Nexus 5000 with 2232 (woodside Fabric Extender (FEX)) is
upgraded to Release 5.2. When the 2232 interfaces connect to 10Gb HP Pass−Thru modules, they flap
continually and eventually error disable:
NDCD29ACCSW1# show int brief | inc linkFlap
Eth152/1/1 2 eth trunk down linkFlapErrDisabled 10G(D) 1001
Eth152/1/2 2 eth trunk down linkFlapErrDisabled 10G(D) 1002
Eth152/1/3 2 eth trunk down linkFlapErrDisabled 10G(D) 1003
Eth152/1/4 2 eth trunk down linkFlapErrDisabled 10G(D) 1004
Eth152/1/5 2 eth trunk down linkFlapErrDisabled 10G(D) 1005
Eth152/1/9 2 eth trunk down linkFlapErrDisabled 10G(D) 1009
There is a known HP 10Gb Pass−Thru module link flap issue documented on the HP website, and they
recommend that customers upgrade to version 1.0.7.0. So far in all of the cases, the HP 10Gb Pass−Thru
firmware is 1.0.1.6
Note: The Pass−Thru module firmware is independent of the HP Onboard Adminstrator (OBA) version.
In order to determine the Pass−Thru module firmware, enter the show interconnect info 11 command:
1. Ethernet 
Product Name: HP 10GbE Pass−Thru Module
Width: Single
URL to Management interface: 
In−Band IPv4 Address: 0.0.0.0
User Assigned Name: 
Part Number: 538113−B21
Spare Part Number: 504624−001
Serial Number: MY31104WWTTemperature Sensor: Present
JS2 Connector: Absent
Internal Ethernet Interface to OA: Absent
Internal Ethernet Route to OA: Enabled
Internal Serial Interface to OA: Present