Cisco Cisco AMP Threat Grid 5500 Appliance Installation Guide
Cisco AMP Threat Grid Appliance Administrator's Guide
ADMINISTRATION
ADMINISTRATION
8
Figure 5 - Enter a New Password
Note:
The command prompt is not always visible in this mode and logging output may be displayed at any point
on top of your input. This does not affect input; you can keep typing "blindly".
3.
Ignore the 2 lines of logging output. Blindly enter the password, press enter, and then retype the password
and enter again. The password will not be displayed.
and enter again. The password will not be displayed.
4.
You MUST type exit from the command line in order for the new password to be saved.
Rebooting will not save the new password. If you do not exit - even though everything appears to be OK -
the password change will be quietly discarded.
the password change will be quietly discarded.
5.
Next, type the command reboot and press Enter to start the appliance in normal mode.
Installing Updates
Before you can update the Threat Grid Appliance with newer versions, you must have completed the initial setup
and configuration steps as described in the Threat Grid Appliance Setup and Configuration Guide .
and configuration steps as described in the Threat Grid Appliance Setup and Configuration Guide .
New Appliances: If you have a new Appliance that shipped with an older version and wish to install updates,
you must complete the initial configuration first. Do Not apply the updates until all Appliance configuration is
done.
you must complete the initial configuration first. Do Not apply the updates until all Appliance configuration is
done.
Appliance updates will not download unless the license is installed, and may not apply correctly if the Appliance
has not been fully configured, including the database.
has not been fully configured, including the database.
Threat Grid Appliance updates are applied through the OpAdmin Portal.
Updates are one-directional: you cannot revert to a previous version after you upgrade to a more recent version.
To test the update, submit a sample for analysis.
1.
From the Operations menu, select Update Appliance.
The updates page opens, displaying the current build of the Appliance: