Cisco Cisco ASR 5000

Page of 9109
ATM Port Configuration Mode Commands   
▀  threshold tx-utilization 
 
 
▄  Command Line Interface Reference, StarOS Release 18 
1614 
   
Important:
  Ports configured for half-duplex do not differentiate between data received and data transmitted. 
Therefore, to avoid redundant alarms, it is recommended that only the receive or transmit utilization threshold be 
configured. 
Alerts or alarms are triggered for transmit port utilization based on the following rules: 
 
Enter condition: Actual percent utilization of a port for transmit data > High Threshold 
 
Clear condition: Actual percent utilization of a port for transmit data < Low Threshold 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval. 
Refer to the 
threshold poll
 command in the Global Configuration Mode Commands chapter of this 
reference to configure the polling interval and the 
threshold monitoring
 command in this chapter to 
enable thresholding for this value. 
Example
 
The following command configures a transmit port high utilization threshold percent of 
70
 and a low 
threshold of 
50
 for an system using the Alarm thresholding model: 
threshold tx-utilization 70 clear 50