Cisco Cisco ASR 5000

Page of 9109
  Global Configuration Mode Commands (T-threshold phspc) 
threshold asngw-handoff-denial  ▀   
 
Command Line Interface Reference, StarOS Release 18  ▄  
 
   
5613 
threshold asngw-handoff-denial 
Configures alarm or alert thresholds for hand-off denials within the ASN-GW service. 
Product
 
ASN-GW 
Privilege
 
Security Administrator, Administrator 
Mode
 
Exec > Global Configuration 
configure
 
Entering the above command sequence results in the following prompt: 
[local]host_name(config)# 
Syntax
 
threshold asngw-handoff-denial high_thresh [ clear low_thresh ] 
default threshold asngw-handoff-denial 
high_thresh
 
Default: 0 
Specifies the high threshold number of hand-off denials that must be met or exceeded within the polling 
interval to generate an alert or alarm. 
high_thresh
 is an integer from 0 through 10000000. A value of 0 disables the threshold. 
clear
 
low_thresh
 
Default: 0 
Specifies the low threshold number of hand-off denials that maintains a previously generated alarm condition. 
If the number of hand-off denials falls beneath the low threshold within the polling interval, a clear alarm will 
be generated. 
low_thresh
 is an integer from 0 through 10000000. A value of 0 disables the threshold. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage 
Use this command to set threshold limits to generate alerts or alarms based on the number of denied hand-off 
that occurred during the specified polling interval. Hand-off denial messages are counted for all ASN 
Gateways that the system is configured to communicate with. 
Alerts or alarms are triggered for hand-off denials based on the following rules: 
 
Enter condition: Actual number of failures is greater than or equal to the high threshold. 
 
Clear condition: Actual number of failures is less than the low threshold. 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval.