Command Line Interface Overview   
▀  Accessing the CLI 
 
 
▄  Command Line Interface Reference, StarOS Release 17 
142 
   
Accessing the CLI 
Access the CLI through the following methods: 
 
Local login through an ASR 5x00 Console port via a serial connection with a management card 
 
Local login through a vConsole port via the hypervisor that initiated the StarOS virtual machine 
 
Remote login using Telnet and Secure Shell (SSH) access to the CLI through any IP interface on the system. 
You can use remote login methods only after the system has been configured to support the various access 
methods. 
Important:
  Even though you can access the CLI remotely through any available IP interface, management traffic 
should be isolated from network traffic by using one of the dedicated management interfaces supported on the ASR 
5x00 platform or StarOS virtual machine. 
Multiple CLI sessions are supported, but the number of sessions varies based on the amount of available memory. The 
Resource Manager reserves enough resources so that as a minimum up to 15 CLI sessions are assured. One of the CLI 
sessions is always reserved for use exclusively by a CLI session on a Console or vConsole interface. Additional CLI 
sessions beyond the pre-reserved set are permitted if sufficient CPU or vCPU resources are available. If the Resource 
Manager is unable to reserve additional resources, you are prompted whether to allow the system to create the new CLI 
session, even without the reserved resources. 
Accessing the CLI Locally Using an ASR 5x00 Console Port 
This section provides instructions for accessing the CLI locally through a Console port on the ASR 5x00 platform. 
Establish a connection between the serial Console port on an ASR 5x00 and a workstation that has a communications 
application that accesses the workstation’s serial port, such as Minicom for Linux or HyperTerminal® for MicroSoft 
Windows®. Refer to the ASR 5x00 Installation Guide for detailed information on connecting to a serial Console port. 
1.  Configure the communications application to support the following:
 
Parameter
 
Setting
 
Baud Rate
 
115,200 bps
 
Data Bits
 
8
 
Parity
 
None
 
Stop Bits
 
1
 
Flow Control
 
None
 
 
Important:
  To change the configuration defined in the table above, modify the terminal 
command located in the Global Configuration Mode. 
2.  At the terminal window, press Enter