Cisco Cisco ASR 5700

Page of 8994
  Channelized Port Configuration Mode Commands 
threshold tx-utilization  ▀   
 
Command Line Interface Reference, StarOS Release 17  ▄  
 
   
2195 
threshold tx-utilization 
Configures thresholds for transmit port utilization. 
Product
 
SGSN 
Privilege
 
Security Administrator, Administrator 
Syntax
 
threshold tx-utilization  high_thresh  [ clear low_thresh ] 
high_thresh
 
Default: 80 
The high threshold transmit port utilization percentage that must be met or exceeded within the polling 
interval to generate an alert or alarm. 
The percentage can be configured to any integer value between 0 and 100. 
clear low_thresh
 
Default: 80 
Allows the configuration of the low threshold. 
The low threshold transmit port utilization percentage that maintains a previously generated alarm condition. 
If the utilization percentage falls below the low threshold within the polling interval, a clear alarm will be 
generated. 
The percentage can be configured to any integer value between 0 and 100. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage 
Transmit port utilization thresholds generate alerts or alarms based on the utilization percentage of each 
configured port in relation to data transmitted during the specified polling interval. This threshold is 
configured on a per-port basis. 
Important:
  Ports configured for half-duplex do not differentiate between data received and data transmitted. 
Therefore, to avoid redundant alarms, it is recommended that only the receive or transmit utilization threshold be 
configured. 
Alerts or alarms are triggered for transmit port utilization based on the following rules: 
 
Enter condition: Actual percent utilization of a port for transmit data ³ High Threshold 
 
Clear condition: Actual percent utilization of a port for transmit data < Low Threshold 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval.