Cisco Cisco Packet Data Gateway (PDG)

Page of 427
GGSN CDR Field Descriptions   
▀  CDR Fields 
 
 
▄  GTPP Interface Administration and Reference, StarOS Release 17 
168 
   
 
Time of first usage: The time stamp for the first IP packet to be transmitted for the service data flow referred to 
the current instance of Service Condition Change. 
 
Time of last usage: The time stamp for the last IP packet to be transmitted for the service data flow referred to 
the current instance of Service Condition Change. 
 
Usage time: The difference between “time of first usage” and “time of last usage”. 
 
User Location Information: The User Location Information for the MS if provided by the SGSN to the GGSN 
during the PDP context activation/modification procedure. 
 
Service change condition: The reason for closing the service data container for triggers like SGSN change, QoS 
change, RAT change, time and volume triggers, etc. 
 
QoS Negotiated: The negotiated QoS applied for the service data flow. 
 
SGSN-address: The valid SGSN IP address during the service data recording interval. 
 
SGSN PLMN identifier: The valid SGSN PLMN Id during the service data recording interval. 
 
FBC data volume uplink: The number of octets transmitted during the use of the packet data services in the 
uplink direction. 
 
FBC data volume downlink: The number of octets transmitted during the use of the packet data services in the 
downlink direction. 
 
Time of Report: A time stamp defining the moment when the service data container is closed. 
 
RAT Type: The valid radio access technology type during the service data recording interval. 
 
Failure handling Continue: A Boolean expression included if the failure handling condition has been executed. 
Present only if the rating group is online (DCCA) charged and if failure handling procedure is executed by 
DCCA. 
Format 
 
Service Identifier: Integer 
 
Rating Group: Integer 
 
Charging Rulebase Name: IA5 octet string 
 
Result Code: Integer 
 
Local Seq No: Integer 
 
Time of first usage: BCD encoded octet string 
 
Time of last usage: BCD encoded octet string 
 
Usage time: Unsigned integer 
 
User Location Information: Octet String 
 
Service change condition: Bit string 
 
QoS negotiated: Octet string 
 
Sgsn-address: Hex value octet string 
 
SGSN PLMN identifier: Hex value octet string 
 
FBC data volume uplink: Integer 
 
FBC data volume downlink: Integer 
 
Time of Report: BCD encoded octet string 
 
Rat Type: Integer (1-255) 
 
Failurehandling Continue: Boolean