Cisco Cisco ASR 5000

Page of 148
Description
Required Information
IPv6 address assigned to the interface.Multiple addresses and subnets are
needed if multiple interfaces will be configured.
IP address and subnet
The physical port to which the interface will be bound. Ports are identified
by the chassis slot number where the line card resides followed by the
number of the physical connector on the card. For example, port 17/1
identifies connector number 1 on the card in slot 17.A single physical port
can facilitate multiple interfaces.
Physical port number
Used when configuring static IP routes from the management interface(s)
to a specific network.
Gateway IP address
MAG Service Configuration
An identification string from 1 to 63 characters (alpha and/or numeric) by
which the MAG service is recognized by the system.
MAG Service Name
Required AAA Context Configuration Information
The following table lists the information that is required to configure the AAA context on an HSGW.
Description
Required Information
Gxa Interface Configuration (to PCRF)
An identification string between 1 and 79 characters (alpha and/or numeric)
by which the interface is recognized by the system.Multiple names are
needed if multiple interfaces will be configured.
Interface name
IPv6 addresses assigned to the interface.Multiple addresses and subnets
are needed if multiple interfaces will be configured.
IP address and subnet
The physical port to which the interface will be bound. Ports are identified
by the chassis slot number where the line card resides followed by the
number of the physical connector on the card. For example, port 17/1
identifies connector number 1 on the card in slot 17.A single physical port
can facilitate multiple interfaces.
Physical port number
Used when configuring static IP routes from the management interface(s)
to a specific network.
Gateway IP address
Gxa Diameter Endpoint Configuration
An identification string from 1 to 63 characters (alpha and/or numeric) by
which the Gxa Diameter endpoint configuration is recognized by the
system.
End point name
An identification string between 1 through 127 characters.The realm is the
Diameter identity. The originator\'s realm is present in all Diameter
messages and is typically the company or service name.
Origin realm name
   HSGW Administration Guide, StarOS Release 19
40
HSGW Configuration
Information Required