S-GW Changes in Release 16   
▀  S-GW Enhancements for 16.1 
 
 
▄  Release Change Reference, StarOS Release 16 
552 
   
S-GW Enhancements for 16.1 
This section identifies all of the S-GW enhancements included in this release: 
Feature Changes - new or modified features or behavior changes. For details, refer to the S-GW Administration Guide 
for this release. 
Command Changes - changes to any of the CLI command syntax. For details, refer to the Command Line Interface 
Reference
 for this release. 
Performance Indicator Changes - new, modified, and deprecated bulk statistics, disconnect reasons, counters and/or 
fields in new or modified schema and/or show command output. For details, refer to the Statistics and Counters 
Reference
 for this release. 
Important:
  This release includes enhancements that are applicable to multiple products. The following lists the 
various multi-product enhancements sections, some of which might include content applicable to your S-GW. 
 
AAA Enhancements  
 
CF Enhancements 
 
ECS Enhancements 
 
Firewall Enhancements 
 
GTPP Enhancements 
 
Lawful Intercept Enhancements 
 
MVG Enhancements 
 
NAT Enhancements 
 
SNMP MIB Enhancements 
 
System and Platform Enhancements 
CSCuj86237 - Inaccurate SGW session stats on standby ASR  
Applicable Products: S-GW 
Feature Changes 
Correction to Inaccurate S-GW Session Statistics on Standby S-GW
 
A behavior change has been introduced as part of the fix for CSCuj86237. 
Previous Behavior:  Previously, the system incremented active and setup counters on a standby S-GW for S-GW 
service statistics when they should only be incremented on the Active S-GW. Similarly, active, setup and release 
counters were incremented on standby the Standby S-GW for S-GW statistics and the S-GW sent these incremented 
counters in bulk statistics. 
New Behavior:  The software has been modified so that the Standby S-GW does not increment setup, release counters 
for S-GW service statistics and S-GW statistics. They will be incremented only when the Standby S-GW becomes