Cisco Cisco ASR 5000
SGSN Service Configuration Procedures
Configuring Gn Interface Selection Based on an Operator Policy (S4 Only, Optional) ▀
SGSN Administration Guide, StarOS Release 18 ▄
Configuring Gn Interface Selection Based on an Operator Policy
(S4 Only, Optional)
The S4-SGSN uses the S4 interface to communicate with EPC-capable UEs. However, operators have the to option to
create a call-control-profile that enables the S4-SGSN to forcefully select the Gn interface for EPC-capable UEs.
create a call-control-profile that enables the S4-SGSN to forcefully select the Gn interface for EPC-capable UEs.
Use this procedure to forcefully select the Gn interface for EPC-capable UEs:
Step 1
Access Call Control Profile Configuration Mode.
Step 2
Create a call-control-profile.
Step 3
Configure the SGSN to forcefully select the Gn interface.
Example Configuration
config
call-control-profile <cc_profile_name>
sgsn-core-nw-interface { gn | s4 }
end
Notes:
sgsn-core-nw-interface specifies the interface that EPC-capable UEs will use to communicate with the packet
core gateways (GGSN/SGW). The default setting for EPC-capable UEs is s4.