Cisco Cisco ASR 5000
InTracer Support for SGSN
Configuring IPMS Server Address ▀
SGSN Administration Guide, StarOS Release 18 ▄
Configuring IPMS Server Address
The following command is used to configure Intelligent Packet Monitoring System (IPMS) server address and ports on
which the IPMS client on the SGSN communicates. This is the IP address and port range of the IPMS server.
which the IPMS client on the SGSN communicates. This is the IP address and port range of the IPMS server.
config
context context_name
ipms
server address ip_address [ seconary ] [ start-port start_port [ end-port
end_port ]][ secondary ]
end_port ]][ secondary ]
no server address ip_address
exit
Notes:
Only when there is an active IPMS server the SGSN generates IPMS events and communicates them to server.
The following command is configured suppress or allow the IPMS-event reporting to Intracer for the specified RAT.
This CLI command helps the operator to change the IPMS-event reporting and manage network load or congestion on
the fly.
This CLI command helps the operator to change the IPMS-event reporting and manage network load or congestion on
the fly.
config
sgsn-global
ipms-suppress [ gprs | umts ]
no ipms-suppress [ gprs | umts ]
exit
Notes:
By default the IPMS event reporting will be done by both the services, provided there is a valid IPMS-context
and IPMS-server configured.
IPMS suppression can be enabled on both the services (GPRS and UMTS service) at the same time. This
provides independent control on the suppression of ipms-events from the GPRS and UMTS services.
Verifying Intracer Support
The show command
show ipms status [all | server address]
is executed to verify Intracer support. On
executing the command the following parameters are displayed:
BSSGP msg
LLC msg
GMM/SM msg