Cisco Cisco ASR 5000

Page of 640
  InTracer Support for SGSN 
Configuring IPMS Server Address  ▀   
SGSN Administration Guide, StarOS Release 18  ▄  
 
   
Configuring IPMS Server Address 
The following command is used to configure Intelligent Packet Monitoring System (IPMS) server address and ports on 
which the IPMS client on the SGSN communicates. This is the IP address and port range of the IPMS server. 
config 
   context context_name 
      ipms 
        server address ip_address [ seconary ] [ start-port start_port [ end-port 
end_port ]][ secondary ]  
        no server address ip_address 
        exit 
Notes: 
 
Only when there is an active IPMS server the SGSN generates IPMS events and communicates them to server. 
The following command is configured suppress or allow the IPMS-event reporting to Intracer for the specified RAT. 
This CLI command helps the operator to change the IPMS-event reporting and manage network load or congestion on 
the fly. 
config 
   sgsn-global 
      ipms-suppress [ gprs | umts ] 
      no ipms-suppress [ gprs | umts ] 
      exit 
Notes: 
 
By default the IPMS event reporting will be done by both the services, provided there is a valid IPMS-context 
and IPMS-server configured. 
 
IPMS suppression can be enabled on both the services (GPRS and UMTS service) at the same time. This 
provides independent control on the suppression of ipms-events from the GPRS and UMTS services. 
Verifying Intracer Support  
The show command 
show ipms status [all | server address]
 is executed to verify Intracer support. On 
executing the command the following parameters are displayed: 
 
BSSGP msg 
 
LLC msg  
 
GMM/SM msg