The Retrieve button requests the current set of fault conditions from the node, card, or network. The window is not updated
when events change on the node. You must click Retrieve to see any changes.
Step 3
If you want to apply exclusion rules, check the Exclude Same Root Cause check box at the node or network view, but
do not check the Exclude Same Root Cause check box in card view.
An exclusion rule eliminates all lower-level alarms or conditions that originate from the same cause. For example, a fiber
break might cause a loss of signal (LOS) alarm, an alarm indication signal (AIS) condition, and a signal fail (SF) condition.
If you check the Exclude Same Root Cause check box, only the LOS alarm will appear. According to Telcordia, exclusion
rules apply to a query of “all conditions from a node.”
Step 4
Return to your originating procedure (NTP).
NTP-G65 Delete Cleared Alarms from Display
Use this procedure to delete Cleared (C) status alarms from the Alarms window or
transient messages from the CTC History window.
Purpose
None
Tools/Equipment
"DLP-G46 Log into CTC" task in the "
document.
Prerequisite Procedures
As needed
Required/As Needed
Onsite or remote
Onsite/Remote
Retrieve or higher
Security Level
Procedure
Step 1
To delete cleared node-level or multishelf-level alarms:
a) In node view (single-shelf mode) or multishelf view (multishelf mode), click the Alarms tab.
b) Click Delete Cleared Alarms.
• If the Autodelete Cleared Alarms check box is checked, an alarm disappears from the window when it is cleared.
• If the Autodelete Cleared Alarms check box is not checked, an alarm remains in the window when it is cleared.
The alarm appears white in the window and has a Clear (CL) severity. The alarm can be removed by clicking the
Delete Cleared Alarms button.
This action removes any cleared ONS 15454 alarms from the Alarms tab. The rows of cleared alarms turn white and
have a C in their status (ST) column.