Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP)

Page of 60
If an alarm is raised on a card, the card type in this slot.
Eqpt Type
If an alarm is raised on a card, the slot where the alarm occurred [appears only in network and node
view (single-shelf mode) or shelf view (multishelf mode)].
Slot
If an alarm is raised on a card, the port where the alarm is raised; for STSTerm and VTTerm, the port
refers to the upstream card it is partnered with.
Port
Indicates how many STSs are contained in the alarmed path. This information complements the alarm
object notation, which is explained in the Cisco ONS 15454 DWDM Troubleshooting Guide
Path Width
Severity level: CR (Critical), MJ (Major), MN (minor), NA (Not Alarmed), NR (Not Reported).
Sev
Status: R (raised), C (clear), T (transient).
ST
When checked, indicates a service-affecting alarm.
SA
The error message/alarm name; these names are alphabetically defined in the Cisco ONS 15454
DWDM Troubleshooting Guide 
.
Cond
Description of the alarm.
Description
The following table lists the color codes for alarm and condition severities.
Table 2: Color Codes for Alarms and Condition Severities
Description
Color
Raised Critical (CR) alarm
Red
Raised Major (MJ) alarm
Orange
Raised Minor (MN) alarm
Yellow
Raised Not Alarmed (NA) condition
Magenta (pink)
Raised Not Reported (NR) condition
Blue
Cleared (C) alarm or condition
White
This section contains the following topics.
Viewing Alarms by Time Zone
By default, alarms and conditions are displayed with the time stamp of the CTC workstation where you are viewing them. However,
you can set the node to report alarms (and conditions) using the time zone where the node is located.