In the Preference General tabs, the Maximum History Entries value only applies to the Session window.
Note
Different views of CTC display different kinds of history:
• The History > Session window is shown in network view, node view (single-shelf mode) or shelf view (multishelf mode), and
card view. It shows alarms and conditions that occurred during the current user CTC session.
• The History > Shelf window is only shown in node view (single-shelf mode) or shelf view (multishelf mode). It shows the
alarms and conditions that occurred on the node since CTC software was operated on the node.
• The History > Card window is only shown in card view. It shows the alarms and conditions that occurred on the card since
CTC software was installed on the node.
Double-click an alarm in the History window to display the corresponding view. For example,
double-clicking a card alarm takes you to card view. In network view, double-clicking a node alarm takes
you to node view (single-shelf mode) or shelf view (multishelf mode).
Tip
If you check the History window Alarms check box, you display the node history of alarms. If you check the Events check box, you
display the node history of Not Alarmed and transient events (conditions). If you check both check boxes, you retrieve node history
for both.
History Column Descriptions
The following table lists the History window column headings and the information recorded in each column.
Table 6: History Column Description
Information Recorded
Column
Num (number) is the quantity of alarm messages received, and is incremented automatically as
alarms occur to display the current total of received error messages. (The column is hidden by default;
to view it, right-click a column and choose Show Column > Num.)
Num
Ref (reference) is a unique identification number assigned to each alarm to reference a specific alarm
message that is displayed. (The column is hidden by default; to view it, right-click a column and
choose Show Column > Ref.)
Ref
Date and time of the condition.
Date
Shows the name of the node where the condition or alarm occurred. (Visible in network view.)
Node
TL1 AID for the condition object. For an STSmon or VTmon, the object.
Object
Slot where the condition occurred [only displays in network view and node view (single-shelf mode)
or shelf view (multishelf mode)].
Slot
Port where the condition occurred. For STSTerm and VTTerm, the port refers to the upstream card
it is partnered with.
Port