Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP)

Page of 23
Procedure
Step 1
In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Timing > Source tabs.
Step 2
Find the Clock reference that is currently set to Manual or Force in the Operation drop-down list.
Step 3
From the Operation drop-down list, choose Clear .
Step 4
Click Apply.
Step 5
Click Yes in the confirmation dialog box. If the normal timing reference is an acceptable valid reference, the node switches
back to the normal timing reference as defined by the system configuration. If the normal timing reference is invalid or
has failed, a warning dialog box appears. Click OK; the timing reference will not revert.
Step 6
Return to your originating procedure (NTP).
NTP-G113 View the NCS Timing Report
This procedure displays the current status of the NCS timing
references.
Purpose
None
Tools/Equipment
"DLP-G46 Log into CTC" task in
document.
Prerequisite Procedures
As needed
Required/As Needed
Onsite or remote
Onsite/Remote
Maintenance or higher
Security Level
Procedure
Step 1
In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Timing > Report tabs.
Step 2
In the Timing Report area, you can view node timing information. The date and time of the report appear at the top of the
report. The time stamp is the same as the alarms time stamp and can be configured using the DLP-G118 Display Alarms
and Conditions Using Time Zone task in the
document.
Step 3
To update the report, click Refresh. The following table describes the report fields and entries.
14