Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP) Data Sheet

Page of 13
 
 
© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. 
Page 9 of 13 
ANSI System 
ETSI System  
Laser 
●  UL 60950-1 - Edition 2, March 2007 
●  IEC 60825-1: 2001 Ed.1.2 (incl. am1+am2) Safety 
of laser products Part 1: Equipment classification, 
requirements and users guide 
●  IEC60825-2 Ed.3 (2004) Safety of laser products 
Part 2: Safety of optical fiber communication 
systems + A1:2006 
●  IEC 60825-1: 2001 Ed.1.2 (incl. am1+am2) Safety of laser products Part 1: 
Equipment classification, requirements and users guide 
●  IEC60825-2 Ed.3 (2004) Safety of laser products Part 2: Safety of optical fibre 
communication systems + A1:2006 
●  21CFR1040 (2008/04) (Accession Letter and CDRH Report) Automatic Laser 
Shutdown and restart (ALS) according to ITU-T G.664 (03/06). Guidance for Industry 
and FDA Staff (Laser Notice No. 50) , June 2007 
●  Laser Products – Conformance with IEC 60825-1 and IEC 60601-2-22; Guidance for 
Industry and FDA Staff (Laser Notice No. 50), June 2007 
Environmental 
●  GR-63-CORE Issue 3, NEBS Physical Protection, 
March 2006  
●  ETS 300-019-2-1 V2.1.2 (Storage, Class 1.1) 
●  ETS 300-019-2-2 V2.1.2 (1999-09): Transportation, Class 2.3 
●  ETS 300-019-2-3 V2.2.2 (2003-04):Operational, Class 3.1E 
Optical 
●  GR-253-CORE - Issue 04  
●  ITU-T G.691 
●  ITU-T G.709 
●  ITU-T G.975 
Quality 
●  TR-NWT-000332, Issue 4, Method 1 calculation for 20-year mean time between failure (MTBF) 
Miscellaneous 
●  GR-1089-CORE Issue 4, NEBS EMC and Safety (June 2006) (Note: NEBS-1) 
●  GR-63-CORE Issue 3, NEBS Physical Protection (March 2006) (Note: NEBS-2) 
●  ATT-TP-76200: 2008  
●  ANSI T1.315-2001 
●  GR-499: 2004 Transport Systems Generic Requirements (TSGR): Common Requirements 
Table 4. 
System Requirements  
Component 
Cisco ONS 15454 ANSI 
Cisco ONS 15454 ETSI 
Cisco ONS15454 M6 
Cisco ONS15454 M2 
Processor 
TCC3/TCC2P/TCC2 
TCC3/TCC2P/TCC2 
TNC/TSC 
TNC/TSC 
Cross-connect 
All (not required) 
All (not required) 
– 
– 
Shelf assembly 
15454-SA-HD or 15454-SA-
HD-DDR shelf assembly with 
CC-FTA version fan-tray 
assembly 
15454-SA-ETSI shelf 
assembly with CC-FTA fan-
tray assembly 
15454-M6-SA shelf 
assembly 
15454-M2-SA shelf 
assembly 
System software 
Release 9.2.1 ANSI or later 
Release 9.2.1 ETSI or later  
Release 9.2.1 ANSI/ETSI 
or later  
Release 9.2.1 ANSI/ETSI 
or later  
Slot compatibility 
– 6, 12 – 17 
– 6, 12 – 17 
– 7 
– 3 
Table 5. 
Client Side Specifications 
Specification 
VSR Interface 
ITU G.693 SONET/SDH 
 
 
ITU G.693 OTU3 
VSR2000-3R2
2
 
VSR2000-3R3
3
 
VSR2000-3R5
3
 
VSR2000-3R2F
2, 4
 
VSR2000-3R3F
3, 4
 
VSR2000-3R5F
3
 
Automatic laser shutdown and restart 
ITU-T G.664 
Unamplified targeted fiber distance, SMF28
1
 
(FD
smf28
2 km 
Nominal wavelength (
Tnom
1550 nm 
Optical transmitter 
Operating wavelength range (
Tmin
 to 
Tmax
1530 nm to 1565 nm