Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP) Release Notes

Page of 11
◦Mozilla Firefox
◦Safari
◦Google Chrome
Critical Bug Fixes in Release 10.1.0.2
The following critical issues have been resolved in Release 10.1.0.2:
• The USB-WRITE-FAIL alarm is raised when the node is loaded with multiple parallel operations such as:
• Bulk Performance Monitoring retrieval
• Database deletion
• Online Insertion and Removal of the LCD module
• Reset of the standby controller.
• The Subtended Shelf Controller fails to activate and the USB-WRITE-FAIL alarm is raised due to sudden disconnect or Data
Migration Assistant (DMA) timeout during software upgrade.
• The DBOSYNC, BKUPMEMP, and EQPT-FAIL alarms are raised when standby controller card (TNC/TSC and TNC-E/TSC-E)
loses all the raw file system descriptors.
• When soft reboot is performed on the active TNC card from gateway network element (GNE), the End Network Element (ENE)
is not discovered in CTC.
• The 10x10G-LC, 100G-LC-C, 100G-CK-C, 100GS-CK-LC, and 200G-CK-LC cards reset automatically without traffic loss.
• The EQPT-DEGRADE alarm is raised on WSE card due to improper socks update on GNE.
Critical Bug Fixes in Release 10.1.0.1
The following critical issues have been resolved in Release 10.1.0.1:
• The EQPT-FAIL alarm is raised on the control card when the nodes are upgraded to R10.0.2.
• The subtended shelf controller with TCC2 card in ONS 15454 shelf running the R10.1 software does not work with the node
controller with TNC/TSC/TNC-E/TSC-E card in ONS 15454 M6 shelf running the software earlier than R10.1.
• The USB-WRITE-FAIL transient alarm is raised and clears on the control card occasionally during the software upgrade.
• When the subtended shelf controller in ONS 15454 M6 shelf is reset after the software upgrade, the active and standby control
card does not communicate.
• The network element loses connectivity with CTC after the node is upgraded from R9.6.0.5 to R10.0.2. The control card is also
reset and the EQPT-FAIL alarm is raised on the control card.
• The TNC card reloads due to invalid address or content of the messages in the Alarm module pipe.
• The virtual provisionable patch cord (PPC) creation fails when CTC attempts to create the PPC from the Network View >
Provisioning > PPC > Create PPC Term pane.
3