Procedure
Step 1
Complete the “NTP-G139 Verify Cisco Transport Planner Reports and Files” task in the chapter “Turn Up a Node” of the
Cisco ONS 15454 DWDM Network Configuration Guide to verify that you have the files and reports prepared by Cisco
Transport Planner for the ROADM node.
Step 2
Complete the "DLP-G46 Log into CTC" task in the "
document at the line amplifier
node.
Step 3
Click the Circuits tab.
Step 4
Make a list of the following OCHNCs, OCH trails, and OCHCCs that pass through the node on the express path for both
the Side B-to-Side A and Side A-to-Side B directions.
You will delete the optical channel circuits in the next step and use the list to recreate the circuits later. Do not
proceed until you complete the circuit list.
Caution
Step 5
Delete the circuits identified in
Step 4, on page 25
using one or more of the following tasks:
• “DLP-G347 Delete Optical Channel Client Connections” task in the chapter “Create Optical Channel Circuits and
Provisionable Patchcords” of the Cisco ONS 15454 DWDM Network Configuration Guide
• “DLP-G418 Delete an Optical Channel Trail” task in the chapter “Create Optical Channel Circuits and Provisionable
Patchcords” of the Cisco ONS 15454 DWDM Network Configuration Guide
• “DLP-G106 Delete Optical Channel Network Connections” task in the chapter “Create Optical Channel Circuits and
Provisionable Patchcords” of the Cisco ONS 15454 DWDM Network Configuration Guide
Step 6
Click the Provisioning WDM-ANS Internal Patchcords tabs.
Step 7
In the internal patchcords table, click the OPT-PRE COM-TX to OPT-BST COM-RX internal patchcord.
Step 8
Click Delete.
Step 9
In the confirmation dialog box, click OK.
Step 10
Remove the physical fiber and attenuators, if present, that connect the COM-TX to COM-RX ports and COM-RX to
COM-TX ports between the OPT-BST and OPT-PRE cards installed in Side B.
Step 11
Referring to the Cisco Transport Planner Shelf Layout report, install one of the following sets of cards on both Side B and
Side A of the node as described by the Cisco Transport Planner NE Update file:
• 32WSS and 32DMX cards
• 32WSS-L and 32DMX-L cards
• 40-WSS-C/40-WSS-CE and 40-DMX-C/40-DMX-CE cards
Step 12
Referring to the Cisco Transport Planner Internal Connections report, connect the fibers to the new wavelength selective
switch and demultiplexer cards.
Step 13
Complete the “NTP-G143 Import the Cisco Transport Planner NE Update Configuration File” procedure in the chapter
“Turn Up a Node” of the Cisco ONS 15454 DWDM Network Configuration Guide
Step 14
Verify that the new internal patchcords are created for the physical cables connected to the new wavelength selective
switch and demultiplexer cards in
Step 12, on page 25
. If not, complete the “NTP-G242 Create an Internal Patchcord
25