The CERENT-MSDWDM-MIB.mib, CERENT-FC-MIB.mib, and CERENT-GENERIC-PM-MIB.mib
in the CiscoV2 directory support 64-bit performance monitoring counters. The SNMPv1 MIB in the
CiscoV1 directory does not contain 64-bit performance monitoring counters, but supports the lower and
higher word values of the corresponding 64-bit counter. The other MIB files in the CiscoV1 and CiscoV2
directories are identical in content and differ only in format.
Note
In Software Release 9.60 and later, selecting the CERENT-GENERIC-MIB file in ONS 15454 M2 or
ONS 15454 M6 displays trap names that are prefixed with g.
Note
It is recommended that the SNMP Manager timeout value be set to 60 seconds. Under certain conditions,
if this value is lower than the recommended time, the TCC card can reset. However, the response time
depends on various parameters such as object being queried, complexity of what and number of hops in
the node, etc.
Note
The port names configured in CTC and TL1 can be up to 80 characters; however, SNMP accepts only up
to 64 characters for port names.
Note
The SNMP management interface supports the IEEE 802.3 LAG MIB.
The following figure illustrates the basic layout idea of an SNMP-managed network.
Figure 1: Basic Network Managed by SNMP
Basic SNMP Components
In general terms, an SNMP-managed network consists of a management system, agents, and managed devices.