Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP)

Page of 100
"DLP-G46 Log into CTC" task at
document.
Prerequisite Procedures
As needed
Required/As Needed
Onsite or remote
Onsite/Remote
Retrieve or higher
Security Level
Procedure
Step 1
In node view (single-shelf mode), or shelf view (multishelf mode), double-click the DWDM, TXP, or MXP card where
you want to change the PM count display interval. The card view appears.
Step 2
Click the Performance tab.
Step 3
If you want to change the PM interval to 15 minutes for a subtab, click the relevant subtab(s), located on the left side of
the Performance tab.
Performance subtabs vary depending on the
card.
Note
Step 4
If you want to change the PM interval to 15 minutes for a specific port, select the port from the Ports drop-down list (where
available).
Step 5
To go to any of the tabs, subtabs, or ports (found in the Ports drop-down list where available) for the card where you want
to set the PM count interval, click the subtab and choose the port, if applicable from the drop-down list.
Step 6
Click the 15 min radio button.
Step 7
Click Refresh . PM parameters appear in 15-minute intervals synchronized with the time of day.
Step 8
View the Curr column to find PM counts for the current 15-minute interval.
Each monitored performance parameter has corresponding threshold values for the current time period. If the value of the
counter exceeds the threshold value for a particular 15-minute interval, a threshold crossing alert (TCA) is raised. The
number represents the counter value for each specific PM parameter.
Step 9
View the Prev-columns to find PM counts for the previous 15-minute intervals.
If a complete 15-minute interval count is not possible, the value appears with a yellow background. An incomplete
or incorrect count can be caused by monitoring for less than 15 minutes after the counter started, changing the
node timing settings, changing the time zone settings, replacing a card, resetting a card, or changing port service
states. When the problem is corrected, the subsequent 15-minute interval appears with a white background.
Note
Step 10
Return to your originating procedure (NTP).
DLP-G132 Refresh PM Counts at One-Day Intervals
This task changes the window view to display PM parameters
in 1-day intervals.
Purpose
None
Tools/Equipment