Cisco Cisco Broadband Access Center Telco Wireless 3.8

Page of 267
 
8-17
Cisco Broadband Access Center for Cable Administrator’s Guide
OL-2445-02
Chapter 8      Broadband Access Center for Cable Support Tools and Advanced Concepts
The Configuration File Utility
Specifying Macro Variables at the Command Line
Usage Guidelines
You use the runCfgUtil.sh command to specify macro variables.
Syntax Description
You must use this syntax when using the unCfgUtil.sh command when specifying macro variables at 
the command line:
runCfgUtil.sh -l <file> -m <"key_value_pairs”>
Where:
-l—Specifies the input file is on the local file system.
<file>—Identifies the input template file being parsed.
-m—Identifies the username to use when connecting to the RDU.
<“key_value_pairs”>—Identifies the key value pairs for macro variables. When multiple macro 
variables are required, a double comma separator is inserted between the key value pairs.
To specify values for macro variables at the command line:
Step 1
Change directory to /opt/CSCObpr/rdu/samples/templates. 
Step 2
Select a template file to use.
Step 3
Identify the macro variables in the template. In this example, the macro variables are macro1 (option 3) 
and macro11 (option 4.2). 
Step 4
Identify the values for the macro variables. The value for macro1 will be set to 1, and the value for 
macro11 to 64000. 
Step 5
Run the configuration file utility using this command:
runCfgUtil.sh -l macro.tmpl -m "macro1=1,,macro11=64000"
Where:
-unprov.tmpl—Identifies the input file.
macro1=1,,macro11=64000—Identifies the key value pairs for macro variables. Since multiple 
macro variables are necessary, a double comma separator is inserted between the key value pairs.
After running the utility, results similar to these should appear:
# /opt/CSCObpr/rdu/bin/runCfgUtil.sh -l macro.tmpl -m "macro1=1,,macro11=64000"
Broadband Provisioning Registrar Configuration Utility
Version: 2.5.1.5
Outputting binary contents
Off
File Bytes
Option
 Description
Value
 0   
 030101    
 3   
 Network Access Control     
 On          
 3  
 041F  
 4   
 Class of Service       
 5 
 010101 
 4.1   
 Class ID        
 1        
 8  
 02040000FA00 
4.2  
Maximum Downstream Rate      
 64000 bits/sec  
 14
 03040000FA00 
4.3 
Maximum Upstream Rate       
 64000 bits/sec