Cisco Cisco Transport Manager 9.1 Technical References

Page of 151
MTNM IMPLEMENTATION STATEMENT TEMPLATES AND GUIDELINES  
TMF 814Av3.0 
  TeleManagement Forum 2003 
18 
2.6.2  Interfaces 
Table 2-14. EmsSessionFactory 
Operation Status 
Support 
Exception/ 
Error Reason  
Comments 
getEmsSession M 
ProcessingFailure
Exception<Propert
y enable-gwcorba-
encryption 
obtained is null.> 
ProcessingFailure
Exception<
 
Exception thrown 
while Decrypting 
the User/Password 
-> 
ProcessingFailure
Exception<
 
Property enable-
gwcorba-
encryption 
obtained is 
invalid.> 
ProcessingFailure
Exception<
 
Unable 
to get enable-
gwcorba-
encryption from 
properties:> 
ProcessingFailure
Exception<
 
Length 
of User name must 
be at least one and 
maximum of 53.> 
ProcessingFailure
Exception<
 
Length 
of Password must 
be at least one and 
maximum of 53.> 
ProcessingFailure
Exception<
 
Cannot login. All 
s_maxnumsession 
sessions are in 
use.> 
This operation is accessed via a 
user name and password. The OSS 
username and password is set via 
CTM’s Administration options. CTM 
allows users to send encrypted 
username and password. To use 
this option NMS must obtain the 
public key using 
getEMSPublicKeyPairs() method 
(defined in more detail in CTM 
Gateway/CORBA Implementation 
Agreement).  
CTM allows only a configurable  
number of clients, ranging between 
4 to 24,  to access Gateway 
CORBA simultaneously. The 
maximum number of sessions that 
can be open simultaneously is 25. 
The default setting for maximum of 
clients is 8.   
2.6.3  Notifications 
There are no specific notifications associated with the data types in this module. 
2.7  Equipment Module 
2.7.1  Data Types