Name
 
Type
 
Input/ 
Output
 
Description
 
EventList
 
notifications::EventList_T
 
Out
 
First batch of alarms
 
EventIt
 
notifications::EventIterator_I
 
Out
 
Iterator to retrieve the 
remaining alarms.
 
3.3.9  setAdditionalInfo 
Synopsis  
Description 
This interface allows you to change the note of an alarm. You can use setAdditionalInfo to 
perform an append, replace, or delete operation for an alarm. This is applicable for alarms at 
the EMS/NE level. 
Name
 
Type
 
Input/ 
Output
 
Description
 
objectName
 
globaldefs::NamingAttributes_T
 
In
 
Alarm AID that is the target for note 
changes.
 
additionalInfo
 
globaldefs::NVSList_T
 
In
 
List of additional information for the 
alarm. This parameter must not be null 
or empty.
 
additionalInfo must contain one of the parameters in the following table, where Key and Value 
are the NameAndStringValue_T fields: 
Key
 
Value
 
Description
 
note_append
 
String
 
Note to append to an existing note.
 
note_replace
 
String
 
Note to replace.
 
note_delete
 
String
 
Note to delete.
 
To address EMS alarms, AID must be used without ManagedElement: 
•  objectName [0] = new NameAndStringValue_T("EMS", "Cisco Systems/Prime Optical") 
•  objectName [1] = new NameAndStringValue_T("AID", "notificationId=10"); 
The EMS generates an AVC event each time this API is called. 