Parameters
Name
Type
Input/Output Description
holdingTime HoldingTime_T Out
Time period (in hours) within which 15-minute
and 24-hour PM data records can be retrieved.
and 24-hour PM data records can be retrieved.
Prime Optical support for the HoldingTime_T structure is as follows:
• Short storeTime24hr—Minimum store time, in hours, for 24-hour data. Prime Optical
reports 0 if PM data is held indefinitely.
• Short storeTime15min—Minimum store time, in hours, for 15-minute data. Prime Optical
reports 0 if PM data is held indefinitely.
Throws
Compliance
TMF-defined.
3.13.10 getAllCurrentPMData
Synopsis
Description
This interface enables an NMS to request a filtered set (scoped by the input parameter
pmParameters) of the current PM data for a list of TP measurement points. Within the request
for each measurement point, granularity (15 min, 24 hr, N/A) and location (nearEnd, farEnd,
bidirectional) can be specified. The operation mode is best effort.
pmParameters) of the current PM data for a list of TP measurement points. Within the request
for each measurement point, granularity (15 min, 24 hr, N/A) and location (nearEnd, farEnd,
bidirectional) can be specified. The operation mode is best effort.
Current data is generally marked as incomplete, as the current bin is not completed. If no PM
data is available as specified, an empty list is returned.
data is available as specified, an empty list is returned.
This interface uses an iterator to allow the NMS to handle a large number of objects.
If the layer rate is L3_Optical_Channel (which requires a DWDM CTP), Prime Optical uses the
naming convention defined in the TMF for the CTP.