Cisco Cisco Prime Optical 9.8 Developer's Guide

Page of 762
Cisco Prime Optical 9.8 GateWay/CORBA Programmer Reference Guide 
OL-29218-01
 
 
602
 
Description 
This interface returns the SubnetworkConnection structure for the TP tunnel SNC identified by 
the sncName. Because TP tunnel names are not guaranteed to be unique in the network, you 
must provide the TP tunnel name in the following format: 
<Native TP-Tunnel name>:TKEY=<TP-Tunnel key>  
For example, tunnel192_193:TKEY=3.3.3.0:55:5.5.5.0:66. 
The BFD template order follows the order of the aEnd and zEnd endpoints of the TP tunnel. 
Because the order is not stored in the ME, it depends on the order of discovery. The TKEY is 
composed as follows: 
<source Node ID>:<source Tunnel ID>:<dest Node ID>:<dest Tunnel ID> 
The TKEY remains invariant with the order of discovery. 
Relevant Data Structures 
 
The following table describes the additionalInfo parameters. 
Parameter Name
 
Valid 
Values
 
Description
 
workLspName
 
String 
 
Name of the working LSP circuit.
 
workLspSid
 
Integer
 
SID of the working LSP circuit.
 
workLspUniqueID
 
Integer
 
Unique ID of the working LSP circuit.
 
workLspNum
 
Integer
 
Working LSP number.