Cisco Cisco Prime Optical 9.6 Technical References
Cisco Prime Optical 9.6.3 Database Schema
OL-28045-01
237
Column Name
Oracle Data
Type
Type
Integrity
Constraints
Constraints
Description
occurring during the interval.
occurring during the interval.
RsEsr
NUMBER(10)
DEFAULT –1
RS ESR is the ratio of errored seconds to
total seconds in available time during a
fixed measurement interval.
total seconds in available time during a
fixed measurement interval.
RsSesr
NUMBER(10)
DEFAULT –1
RS SESR is the ratio of SES to total seconds
in available time during a fixed
measurement interval.
in available time during a fixed
measurement interval.
RsBber
NUMBER(10)
DEFAULT –1
RS BBER is the ratio of BBE to total blocks
in available time during a fixed
measurement interval. The count of total
blocks excludes all blocks during SESs.
in available time during a fixed
measurement interval. The count of total
blocks excludes all blocks during SESs.
IS24H
NUMBER(1)
NOT NULL
Whether the PM data is collected in 24-
hour or 15-minute increments. Values are:
1: 24 hour
0: 15-minute
hour or 15-minute increments. Values are:
1: 24 hour
0: 15-minute
ModelType
NUMBER(10)
DEFAULT 0
Model type.
ObjectType
NUMBER(10)
DEFAULT 0
Object type.
StrObjInstance
VARCHAR2(256
)
)
—
StrObjInstance name.
InvalidityList
VARCHAR2(102
4)
4)
—
Invalidity list for PM data.
RsOfs
NUMBER(10)
DEFAULT –1
Regenerator section out-of-frame
seconds.
seconds.
StrCorbaTIDAI
D
D
VARCHAR2(512
)
)
—
Stores the TL1 target identifier (TID) value
returned by the getCTMHistoryPMData
API for each physical termination point
(PTP). The getCTMHistoryPMData API
stores the historical PM data output in a
.csv file. The PTP native name is one of the
output parameters displayed in this file. It
contains the rack, shelf, slot, and port
information for the PTP. It also contains
pluggable port module (PPM) information,
if applicable.
returned by the getCTMHistoryPMData
API for each physical termination point
(PTP). The getCTMHistoryPMData API
stores the historical PM data output in a
.csv file. The PTP native name is one of the
output parameters displayed in this file. It
contains the rack, shelf, slot, and port
information for the PTP. It also contains
pluggable port module (PPM) information,
if applicable.
1.1.173
ONS155xx_CDL_Flow_Config
The ONS155xx_CDL_Flow_Config table provides information about the flows within a
CDL-enabled interface for the ONS 155xx.
CDL-enabled interface for the ONS 155xx.
Primary key: CDLFLOW_CONFIG_PK
Tablespace: ONS155XX_DATA_TABLESPACE