2.1.3.2.2  Equipment Service State 
The attribute name is ACTUAL_EQUIPMENT_SERVICE_STATE and is displayed in 
getAdditionalInfo for the equipment. The attribute value for the service state is the same as 
that shown in Prime Optical. 
 
Table 2-2: Equipment Service State–Primary (ONS 15310 CL) 
Primary States (PST-PSTQ)
 
Attribute Value
 
Meaning
 
In Service–Normal (IS_NR)
 
The entity is fully operational and performs as provisioned.
 
Out of Service–Management 
(OOS_MA) 
 
The entity has been administratively removed from service. 
 
Out of Service–Autonomous 
(OOS_AU)
 
The entity is not operational due to an autonomous event.
 
Out of Service–Autonomous 
and Management 
(OOS_AUMA)
 
The entity is not operational due to an autonomous event and has been 
administratively removed from service.
 
Table 2-3: Equipment Service State–Secondary (ONS 15310 CL) 
Secondary States (SST)
 
Attribute Value
 
Meaning
 
Unassigned (UAS)
 
The entity is not provisioned in the database.
 
Unequipped (UEQ)
 
The entity has been removed, leaving an empty slot. It may or may not 
be assigned (provisioned).
 
Mismatch of Equipment and 
Attributes (MEA)
 
Incorrect equipment is installed. For example,  
the card plugged in is not compatible with the 
provisioned card or slot.
 
Automatic In-Service (AINS)
 
The entity is in a delay transition (to IS) state. The transition to IS is 
pending the correction of off-normal conditions on the entity.
 
Maintenance (MT)
 
The entity has been manually removed from 
service for maintenance. It is still capable of 
performing its provisioned functions. Traffic is 
still carried.
 
Disabled (DSBLD)
 
The entity has been manually removed from 
service and cannot perform its provisioned 
functions. All of its provisioned services are 
disrupted. Traffic is not carried.
 
Loopback (LPBK)
 
The loopback command is in effect (any loopback 
type).