Cisco Cisco Prime Optical 9.6 Developer's Guide
Cisco Prime Optical 9.6.3 GateWay/CORBA Programmer Reference Guide
OL-28047-01
35
2.1.3.2.2 Equipment Service State
The attribute name is ACTUAL_EQUIPMENT_SERVICE_STATE and is displayed in
getAdditionalInfo for the equipment. The attribute value for the service state is the same as
that shown in Prime Optical.
Table 2-2: Equipment Service State–Primary (ONS 15310 CL)
Primary States (PST-PSTQ)
Attribute Value
Meaning
In Service–Normal (IS_NR)
The entity is fully operational and performs as provisioned.
Out of Service–Management
(OOS_MA)
The entity has been administratively removed from service.
Out of Service–Autonomous
(OOS_AU)
The entity is not operational due to an autonomous event.
Out of Service–Autonomous
and Management
(OOS_AUMA)
The entity is not operational due to an autonomous event and has been
administratively removed from service.
Table 2-3: Equipment Service State–Secondary (ONS 15310 CL)
Secondary States (SST)
Attribute Value
Meaning
Unassigned (UAS)
The entity is not provisioned in the database.
Unequipped (UEQ)
The entity has been removed, leaving an empty slot. It may or may not
be assigned (provisioned).
Mismatch of Equipment and
Attributes (MEA)
Incorrect equipment is installed. For example,
the card plugged in is not compatible with the
provisioned card or slot.
Automatic In-Service (AINS)
The entity is in a delay transition (to IS) state. The transition to IS is
pending the correction of off-normal conditions on the entity.
Maintenance (MT)
The entity has been manually removed from
service for maintenance. It is still capable of
performing its provisioned functions. Traffic is
still carried.
Disabled (DSBLD)
The entity has been manually removed from
service and cannot perform its provisioned
functions. All of its provisioned services are
disrupted. Traffic is not carried.
Loopback (LPBK)
The loopback command is in effect (any loopback
type).