Cisco Cisco Prime Optical 9.6 Developer's Guide

Page of 818
Cisco Prime Optical 9.6.3 GateWay/CORBA Programmer Reference Guide 
OL-28047-01
 
 
40
 
Primary States (PST-PSTQ)
 
Attribute Value
 
Meaning
 
Out of Service–Autonomous and 
Management (OOS_AUMA)
 
The entity is not operational due to an autonomous event and 
has been administratively removed from service.
 
 
Table 2-6: Equipment Service State–Secondary (ONS 15327) 
Secondary States (SST)
 
Attribute Value
 
Meaning
 
Unassigned (UAS)
 
The entity is not provisioned in the database.
 
Unequipped (UEQ)
 
The entity has been removed, leaving an empty slot. It may or 
may not be assigned (provisioned).
 
Mismatch of Equipment and 
Attributes (MEA)
 
Incorrect equipment is installed. For example, the card plugged 
in is not compatible with the provisioned card or slot.
 
Automatic In-Service (AINS)
 
The entity is in a delay transition (to IS) state. The transition to 
IS is pending the correction of off-normal conditions on the 
entity.
 
Maintenance (MT)
 
The entity has been manually removed from service for 
maintenance. It is still capable of performing its provisioned 
functions. Traffic is still carried.
 
Disabled (DSBLD)
 
The entity has been manually removed from service and cannot 
perform its provisioned functions. All of its provisioned services 
are disrupted. Traffic is not carried.
 
Loopback (LPBK)
 
The loopback command is in effect (any loopback type). 
 
 
2.1.6.3  XTC Cards 
The XTC-14 card has 14 DS1 ports numbered 1 through 14. Only VT1.5 SNCs can be created on 
these ports. The XTC-28-3 card has 28 DS1 ports numbered 1 through 28 and 3 DS3 ports 
numbered 29 through 31. VT1.5 SNCs can be created on DS1 ports, and STS-1 SNCs can be 
created on DS3 ports. 
2.1.6.4  PTPs 
All PTPs are bidirectional for the ONS 15327. The ports are always in channelized mode. PTPs 
support In Service, Out of Service, Out of Service–Maintenance, and Auto in Service values for 
the service state attribute. 
2.1.6.5  CTPs 
All CTPs are in channelized mode for the ONS 15327. Alarm monitoring cannot be turned on or 
off for CTPs.