Cisco Cisco Prime Optical 9.6 Developer's Guide

Page of 818
Cisco Prime Optical 9.6.3 GateWay/CORBA Programmer Reference Guide 
OL-28047-01
 
 
543
 
•  string errorReason—If a best-effort parameter could not be set, the EMS provides the fault 
reason. 
Throws 
Raises ProcessingFailureException: 
EXCPT_INTERNAL_ERROR - Raised in case of nonspecific EMS internal failure. 
EXCPT_INVALID_INPUT - Raised when any input parameter is syntactically 
incorrect. For example, the tpName does not refer to a CPTP TP object. 
EXCPT_ENTITY_NOT_FOUND - Raised when tpName references an object that does not 
exist.  
EXCPT_OBJECT_IN_USE - Raised when the CPTP is an ELL endpoint. 
EXCPT_UNABLE_TO_COMPLY - Raised if the TP cannot be deleted.  
EXCPT_NE_COMM_LOSS - Raised when communication is lost to an ME involved in 
this operation. 
4.5.5.3  setTPData 
Synopsis 
public void setTPData(TPData_T tpInfo, 
                                     TerminationPoint_THolder modifiedTP) 
        throws ProcessingFailureException 
Description 
This interface allows the NMS to set parameters on a specified TP. 
TPData_T 
 
NameAndStringValue_T[]  tpName  
The FTP name built as: 
name="EMS";value="CompanyName/EMSname" 
name="ManagedElement";value="ManagedElementName" 
name="FTP";value="/rack=1/shelf=1/port=nn" 
 
TerminationMode_T  
 
tpMappingMode (not handled NA) 
 
LayeredParameters_T[]   transmissionParams 
 
NameAndStringValue_T[]  ingressTrafficDescriptorName (empty) 
 
NameAndStringValue_T[]  egressTrafficDescriptorName (empty) 
 
LayeredParameters_T 
 
short  
 
 
 
layer 
 
 
 
 
 
i Specify the new layer rate LR_LAG_Freagment 
(305) 
 
NameAndStringValue_T[]  transmissionParams 
The following table lists the transmission parameters. 
Name
 
Value
 
Description