Cisco Prime Optical 9.6.3 GateWay/CORBA Programmer Reference Guide 
OL-28047-01
 
 
62
 
For the ONS 15310 CL, ONS 15310 MA SONET, and ONS 15310 MA SDH, a port on PPM number 
2 is reported as /rack=1/shelf=1/slot=2/ppm_holder=2/port=1. 
For the ONS 15454 SONET and ONS 15454 SDH, a port on PPM number 2 is reported as 
/rack=1/shelf=1/slot=2/ppm_holder=2/port=1. 
For the ONS 15530 and ONS 15540, the PTP name represents the position of the PTP with 
respect to the equipment. It also specifies the CLI name, since there can be more than one 
interface type with the same physical position. Numbering for equipmentHolders and ports 
starts from 0 in the NE. However, the TMF convention is to start numbering from 1 for 
equipmentHolders and ports. Therefore, Prime Optical translates PTP names. 
For example, the wavepatch0/0/0 port (which is present in slot 0, subslot 0 in the NE) is 
reported as /rack=1/shelf=1/slot=1/subslot=1/port=1:wavepatch0/0/0. 
The transparent0/0/0 port (which is present in slot 0, subslot 0 in the NE) is reported as 
/rack=1/shelf=1/slot=1/subslot=1/port=1:transparent0/0/0. 
Some PTPs, such as wdm0/0, do not have an associated port number. In these cases, the port 
number is set to 1. 
Wdm0/0 (which is present in slot 0 and subslot 0 in the NE) is reported as 
/rack=1/shelf=1/slot=1/subslot=1/port=1:wdm0/0. 
Wave0 interface (which is present in slot 0 in the NE) is reported as 
/rack=1/shelf=1/slot=1/port=1:wave0. Because the subslot does not apply to this port, it is 
skipped. 
For unmanaged NEs, the PTP native name is a free-format string. 
For 100G TXP-series cards (100G-LC, 10x10G-LC, and CFP-LC) on ONS 15454 SONET and ONS 
15454 SDH, Prime Optical uses /rack=1/shelf=1/slot=3/ppm_holder=1/port=1 for main payload, 
and /rack=1/shelf=1/slot=3/ppm_holder=1/port=1:<Internal Port Number> for internal ports in 
CFP and CXP. 
For ONS 15454 SONET and SDH NEs, when 10x10G_LC is configured in FANOUT mode, the CXP 
sublanes provisioned on the NE use 
“/rack=1/shelf=1/slot=3/ppm_holder=11/port=1:<portNum>”  
The provisionable <portNum> values are 2,3,4,5,6,7,8,9,10 and 11.  
 
Each of the ports (<portNum>) provisioned under ppm_holder=11 is a main PTP. 
2.2.5.4  Connection Termination Point 
Naming conventions for SONET, SDH, and plesiochronous digital hierarchy (PDH) CTP are 
defined by TMF.814 in a document named objectNaming.html. Prime Optical follows these 
rules. 
For OC-n or STM-n cards on the ONS 15327 R3.3 or later, ONS 15454 SONET R3.2.1 or later, and 
ONS 15454 SDH R3.3 or later, Prime Optical supports STS6c, STS9c, and STS24c layer rates. On 
the ONS 15327 R5.0 or later, ONS 15454 SONET R5.0 or later, and ONS 15454 SDH R5.0 or later,