Cisco Cisco Prime Optical 9.6 Developer's Guide

Page of 818
Cisco Prime Optical 9.6.3 GateWay/CORBA Programmer Reference Guide 
OL-28047-01
 
 
655
 
of an attribute value change event is sent. The notification contains the SNC name and the 
reason for the failure. 
For OCHCC, OCHNC, and OCH trail circuits, you can provide additional GMPLS information 
about the associated SNCs. 
The following table lists the reported attributes. 
Attribute Name
 
Type
 
Description
 
Creation Result
 
String
 
Creation result. For example, circuit creation failed.
 
Error Reason
 
String
 
Describes the reason for the failure.
 
 
Example
 
Fixed Header             Domain             = tmf_mtnm 
                         Type               = NT_ATTRIBUTE_VALUE_CHANGE 
Variable Header          Event Reliability  = 0 
                         Priority           = 0 
                         Timeout            = 864000000000 
 
Filterable Data      [0] notificationId      = AVC-21  
                     [1] objectName          = [0] EMS=Cisco 
Systems/PrimeOptical; [1] SubnetworkConnection=ochnc-unprot-gmpls  
                     [2] objectType          = OT_SUBNETWORK_CONNECTION  
                     [3] objectTypeQualifier =   
                     [4] emsTime             = 20120208223853.0Z  
                     [5] neTime              =   
                     [6] edgePoint           = false  
                     [7] attributeList       = [0]Creation Result=Circuit 
Creation Failed [1]Error Reason=Operation Failed node: 10.58.65.104 No Trunk 
port matching the request   
                      [8] isPropagated        = false  
Remainder of body: 
5.4.4  SubnetworkConnection Name Change - AttributeValueChange 
When the subnetwork connection name is modified from the CORBA client, a new 
AtrributeValueChange event is generated. The following table lists the reported attributes. 
 
Attribute Name
 
Type
 
Description
 
Previous SubnetworkConnection 
Name
 
String
 
Previous name of the subnetwork connection
 
New SubnetworkConnection 
String
 
New name of the subnetwork connection