Cisco Cisco Prime Optical 10.3 Developer's Guide
Cisco Prime Optical 10.3 GateWay/CORBA Programmer Reference Guide
299
– The user VLAN ID to associate with this ML VLAN. If the connection type is
L2ConnectionType_T.L2CT_DOT1Q, the valid port VLAN range is from 2 to 4096. If the
connection type is L2ConnectionType_T.L2CT_UNTAGGED, the port VLAN is ignored.
connection type is L2ConnectionType_T.L2CT_UNTAGGED, the port VLAN is ignored.
• globaldefs::NVSList_T additionalInfo
– Supported. You can specify the customerID and service ID.
Prime Optical support for MLVLAN_T structure is as follows:
• globaldefs::NamingAttributes_T name
– Supported. This field contains three tuples. The first tuple has the EMS value. The second
tuple has the L2 topology name. The third tuple has the ML VLAN ID that is the same as
nativeEMSName.
nativeEMSName.
• string userLabel
– Not supported.
• string nativeEMSName
– Supported. The ML VLAN ID is reported.
• string owner
– Not supported.
• multilayersubnetwork::MLVLANTPDataList_T tpList
– Supported. Specifies the list of all front Ethernet ports and associated service type.
– If the port type on a port cannot be determined, Prime Optical represents the port type as
– If the port type on a port cannot be determined, Prime Optical represents the port type as
L2PortType_T.L2PT_UNKNOWN.
– If the connection type for an ML VLAN on a port cannot be determined, Prime Optical
represents the connection type as L2ConnectionType_T.L2CT_UNKNOWN.
• multiLayerSubnetwork::MLVLANState_T vlanState
– Supported. Valid values are MLVLANState_T.COMPLETE and
MLVLANState_T.INCOMPLETE. A state change event is generated if the VLAN state
changes.
changes.
• globaldefs::NVSList_T additionalInfo
– Supported. The customer ID and service ID are reported.
Throws
Compliance
Prime Optical-defined.
Prime Optical-defined.
3.10.2 modifyMLVLANAddFrontPorts
Synopsis