Cisco Cisco Prime Optical 10.3 Developer's Guide
Cisco Prime Optical 10.3 GateWay/CORBA Programmer Reference Guide
575
4.12 Alarm Summaries
Synopsis
Description
The network can generate Layer 2 service-related alarm summaries on Ethernet ports, channel
group ports, and shelves. You can use the getAllActiveAlarms method to get information about
the alarms.
Provide the meName parameter as shown in the following table.
The network can generate Layer 2 service-related alarm summaries on Ethernet ports, channel
group ports, and shelves. You can use the getAllActiveAlarms method to get information about
the alarms.
Provide the meName parameter as shown in the following table.
Parameter
Name
Name
Value
Type
Type
Example
meName
AID
meName[0] = new NameAndStringValue_T("EMS", "Cisco
Systems/Prime Optical")
Systems/Prime Optical")
meName [1] = new NameAndStringValue_T("ManagedElement", "CTM-
454-141");
454-141");
meName [2] = new NameAndStringValue_T("AID",
"notificationId=10");
"notificationId=10");
4.12.1 Alarm Summary Example—Channel Group Port