Cisco Cisco Prime Optical 9.8 Technical References

Page of 115
MTNM IMPLEMENTATION STATEMENT TEMPLATES AND GUIDELINES  
Note that probableCause qualifier is not necessarily human readable, as its real purpose is to satisfy the second 
point. For instance, if the EMS works internally with a GDMO model, then it might use a GDMO probableCause 
and specificProblems attribute values (which are sequences of integers, not very exciting to read). The 
additionalText parameter is there to tell the human operator what is going on. 
Example 1
Consider a vendor that has a line terminal NE that issues the following native alarms from the same termination 
point and layer rate: 
DegradedSignal 
• 
•  fecUncorrectedBlocks (meaning that our Reed-Solomon Forward Error Correcting algorithm has rejected 
some frames) 
Both these alarms are mapped to the generic probable cause BER_SD (i.e., "signal degraded"). The 
probableCauseQualifier, nativeEMSProbableCause and possibly the additionalText parameters distinguish 
between the two. Note that this saves one the trouble of going to TM Forum MTNM standards group and asking 
for a new probableCause value, and even better, it saves the NMS vendor the trouble of managing a new fault 
condition which from their point of view is equivalent to the other one ("a difference that makes no difference is 
no difference"). 
Example 2
Just consider all the equipment alarms that can be generated by all the equipment vendors. The MTNM interface 
designers intentionally use a single probableCause value “EQPT” for all of them. The implication is that it is not 
expected for the NMS to discriminate between hundreds of equipment conditions.  
2.1.6.2  Threshold Crossing Alerts (TCAs)  
One TCA template should be provided for each supported (or required) PM parameter for which the vendor 
supports thresholding or the service provider requires thresholding. As was the case for the probable cause 
template, a single Threshold template can cover several types of TCA (one TCA for each layer rate associated 
with a PM parameter). It should be noted that for a given PM parameter some parameters in the template may 
vary based on the layer rate. 
Table Error! No text of specified style in document.-7. Threshold Template 
Parameter Format 
Comments/ 
Clarifications 
notificationId 
FREE 
The notificationId is not guaranteed to be 
unique. However, if a vendor does 
support unique Ids, this should be noted.  
objectName FIXED 
 
nativeEMSName FREE 
 
objectType VALUE 
LIST 
The set of object types to which this TCA 
can apply 
 
emsTime 
FIXED 
In cases where the NE does not report 
time, a zero should be returned.  
neTime FIXED 
 
TMF814Av3.1 
TeleManagement Forum 2007 
Page  21 of 115