MTOSI Interface Details 
                                    
 
 
 
 
 
Cisco EPN Manager OSS  Integration  Guide for  MTOSI 
 
 
89 
Carrier Ethernet 
Service Order 
Data 
Data Type 
Applicable to 
Service Type 
Description 
enniName 
String 
Access EPL, 
Access EVPL 
Name of the new ENNI to be created. 
l2cpProfile 
String 
All except EVPL 
Layer 2 Control Protocol Profile. 
Profile that determines how the 
various communication protocols are 
handled. Frames using the various 
protocols are tunneled, or dropped or 
peered. Refer to MEF 6.1 for details. 
Values:  
EPL, Access EPL : MEF Option1 or MEF 
Option2 
Access EVPL: EVPL/EVP-LAN/EVP-Tree 
EP-LAN, EP-Tree : MEF EP-LAN/EP-Tree 
EVP-LAN, EVP-Tree: MEF EVPL/EVP-
LAN/EVP-Tree 
qosProfile 
NamingAttri
buteType 
All except EVP-
Tree 
Service QOS Profile Reference. FDN of 
the existing QOS profile with MD, 
QOS_PROFILE RDNs. 
uniQosProfileRef 
NamingAttri
buteType 
E-LAN, E-TREE 
Uni QoS Profile reference. FDN of the 
existing QOS profile with MD, 
QOS_PROFILE RDNs. 
 
Applies a QoS profile on the UNI itself 
to define the bandwidth profile and 
other quality of service attributes of 
the UNI. If you apply a QoS profile on 
the UNI level, you should not apply a 
QoS profile on the service level. 
portMtuSize 
Integer 
All 
The Maximum Transmission Size, in 
bytes, of a packet passing through the 
interface. The MTU of the UNI must be 
greater than or equal to the MTU 
defined on the service level. 
portSpeedRate 
String 
All 
Port speed. You can reduce the speed 
if this is supported on the port. 
portMode 
String 
All 
Mode – values: 
• FULL DUPLEX—Uses simultaneous 
communication in both directions 
between the UNI and the customer’s 
access switch, assuming that both 
sides support full duplex. If one side 
does not support full duplex, the port 
will be brought down.  
• AUTO NEGOTIATION —Uses the 
mode that is agreed upon between the 
two devices, depending on what is 
supported. Full Duplex will be 
attempted but if one device does not 
support it, half duplex will be used.