Cisco Cisco Prime Central 1.3 Release Notes

Page of 8
6
Cisco Prime Central 1.3 Release Notes
OL-28575-02
  Prime Central 1.3 Bugs
The Synchronize dialog box does not indicate when the last synchronization took place.
This problem was observed in a setup with 470 Unified Computing System (UCS) devices where one Prime 
Network instance is associated with Prime Central. To reproduce the problem:
1.
From the Prime Central main menu, select Assure > Services > Data Center and then click the 
Compute tab.
2.
In the Compute Service pane, click Synchronize.
3.
In the Synchronize dialog box, select a synchronization option and then click Sync Now.
4.
From the Prime Central main menu, select Inventory > Common Inventory > Devices.
5.
In the Common Inventory portlet, click Synchronize.
6.
In the Synchronize dialog box, select a synchronization option and then click Sync Now.
Wait a few minutes before proceeding to the next step.
7.
Navigate back to the Compute Service pane and click Synchronize.
The Synchronize dialog box indicates that synchronization has completed, even though it has not yet.
8.
Close and then reopen the Synchronize dialog box.
Instead of indicating when the last synchronization completed, the Synchronize dialog box displays 
NA
.
When a VPN is selected in Prime Central, no data is displayed after cross-launching Prime Performance 
Manager. This problem occurs after completing the following steps:
1.
From the Prime Central main menu, select Assure > Services > Data Center and then click the Network 
tab.
2.
Do one of the following for a VPN:
  –
Click its Expand icon to open the VPN Dashboard.
  –
Open its 360° view.
3.
Click the Prime Performance Manager icon to cross-launch the application.
Even if data is available, Prime Performance Manager displays the message 
data unavailable for report
.
CSCun76563
With Prime Central running in Internet Explorer 8, you are unable to save changes made in the following 
locations:
  •
Audit Log - Configuration dialog box (Administration > System > Audit Log > Options icon > 
Configuration
)
  •
User Management - Configuration dialog box (Administration > User and Privilege Management > 
Users > Options icon > Configuration
)
To save changes in these dialog boxes, you need to run Prime Central in Internet Explorer 9, Firefox 24, or 
Firefox 24 Extended Support Release.
Note
are also specific to Prime Central running in Internet Explorer 8.
CSCun97399
Contextual cross-launch of the Cisco ME 4600 Series Agora-NG EMS from the Common Inventory portlet 
may occasionally not work due to Agora-NG’s inability to fully discover certain ME 4600 Series devices, 
such as the ME 4620. (Refer to 
CSCun59574
 for a description of the root cause of this problem.)
ME 4600 OS 3.1.1 is limited to three concurrent connections. Typically, each management component uses 
at least one connection, and when more than three management components connect to same ME 4600 Series 
device, this issue can occur.