Cisco Cisco Process Orchestrator 3.1 User Guide

Page of 786
 
13-105
Cisco Process Orchestrator 3.1 User Guide
 
Appendix 13      Using Adapters
  Microsoft System Center Operations Manager (SCOM) Adapter
  •
Monitor class name—Name of the monitor class in SCOM to which the monitor object belongs.
  •
Monitor object full name—The full name of the monitor object in SCOM. This is typically the 
computer name of the machine being monitored.
  •
Object name—The name of the object in SCOM from which you want to obtain performance data.
  •
Counter name—The name of the performance counter in SCOM.
  •
Instance name—The name of the instance in SCOM from which to obtain data.
Click Browse to launch the Select SCOM Performance Counter dialog box and connect to the 
SCOM management server. For additional information about connecting to the SCOM management 
server, see 
  •
Performance values generated within the last—Time frame (in seconds, minutes, or hours) of 
collected performance data to be gathered by Process Orchestrator. Enter a numeric value in the text 
box or select the value using the scroll buttons.
  •
Only return the latest performance counter—Check this check box to collect only the latest 
performance counter.
  •
Fail if no values are found—Check this check box to fail the activity if no values match.
Step 5
Click OK. The fields on the Collect SCOM Performance Counter property page populates with the 
selected information.
Searching for an Alert Source
Use the following steps to search for the appropriate alert source details for the SCOM alert.
Step 1
On the SCOM Alert Properties dialog, click Browse to launch the Select Monitor Class and Object 
dialog box to enter the credentials for connecting to the SCOM management server.
Step 2
Choose SCOM Connection and specify the appropriate information to connect to the SCOM 
Management Server.
Step 3
Click Connect to connect to the server.
The Alert source class and Alert source name drop-down lists populate with options after the connection 
to the SCOM Management server is d.
Step 4
Select the appropriate Alert source options, including:
  •
Alert source class—The name of the monitor class in SCOM to which the monitor object belongs.
  •
Alert source name—The fully-qualified name of the monitor object.
  •
Browse—To search for the appropriate alert source, click this button to launch the Select Monitor 
Class and Object dialog box to connect to the SCOM management server and select the monitor 
class name and monitor class object. 
  •
Alert severity level—The severity level of the alert in SCOM that must be matched before the 
process executes. Check one or more of the following check boxes to indicate the severity level of 
alerts that are to be matched:
  –
Information
  –
Critical
  –
Warning