Cisco Cisco Prime Home 2.4 Developer's Guide
Cisco Prime Home – Integration Guide
OL-28557-01 v5.0.1
29
Troubleshooting
When Working with Documents
Revision Conflict
Problem: A 400 status caused by updating an out-of-date revision.
Example:
Response Status
HTTP/1.1 400 revision is out of date; provided=86183852,
existing=86183853
existing=86183853
Solution: Re-fetch the data, re-apply modifications to the fresh data, and re-
submit.
Invalid Data
Problem: A 400 status caused by an invalid data type
Example:
String instead of an integer
{
"id":"1234"
}
Solution: Refer to the WADL documentation for the correct data types.
Problem: A 400 status caused by an illegal reference
Example:
Invalid service name
{
"service": {
"name":"a service name that does not exist", "status":"ENABLED"
}
}
Solution: Ensure service names, labels and any other names which refer to
something else are correct.
Problem: A 400 status caused by a data validation error.
Examples:
WIFI Key is Too Short for WPA
{
"settings": {