Cisco Cisco 1 GHz GainStar Node Data Sheet

Page of 10
 
 
Data Sheet 
©  2010-2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 7 of 10 
Table 6. 
Electrical Specifications 
Item 
Units 
Value 
Electrical 
Max. AC Through Current (continuous) 
Amps 
 
10 
Max. AC Through Current (surge) 
Amps 
 
15 
Table 7. 
Station Powering Data (40-90 V) 
Station Powering Data 
 
DC
 * 
 
AC Voltage 
 
90 
85 
80 
75 
70 
65 
60 
55 
50 
45 
40 
1 RX 
1 TX 
0.82 
AC 
Current  
(A) 
0.30 
0.31 
0.33 
0.34 
0.36 
0.38 
0.42 
0.43 
0.47 
0.52 
0.58 
Power  
(W) 
16.0 
16.0 
15.9 
15.9 
15.9 
15.9 
15.9 
16.0 
16.0 
16.1 
16.3 
*Data is based on stations configured for 2-way operation. AC currents specified are based on measurements made with 
typical CATV type ferroresonant AC power supply (quasi-square wave), 
Table 8. 
Station Powering Data  (100-240 V) 
Station Powering Data 
 
I DC * 
 
AC Voltage 
 
240 
230 
220 
210 
200 
190 
180 
170 
160 
150 
140 
130 
120 
110 
100 
1 RX 
1 TX 
0.82 
AC 
Current 
(A) 
0.14 
0.15 
0.15 
0.16 
0.16 
0.17 
0.17 
0.18 
0.19 
0.12 
0.21 
0.22 
0.23 
0.25 
0.26 
Power 
(W) 
16.3 
16.3 
16.3 
16.2 
16.1 
16.0 
16.0 
16.0 
15.9 
15.8 
15.8 
15.8 
15.7 
15.7 
15.7 
*Data is based on stations configured for 2-way operation. AC currents specified are based on measurements  made with typical CATV type ferroresonant 
AC power supply (quasi-square wave), 
Table 9. 
Mechanical and Environmental Specifications 
Item 
Units 
Value 
Mechanical
 
Water/Dust Ingress Rating 
– 
IP68 
Dimensions (H x W x D) 
 
mm 
in. 
Strand 
Pedestal 
90 x 234 x 212 
3.5 x 9.2 x 8.4 
90 x 250 x 197 
3.5 x 9.9 x 7.8 
Weight 
kg 
lb 
3.0 
6.6 
Environmental 
Operating Temperature 
–40 to +60 
–40 to +140 
Storage Temperature 
–40 to +85 
–40 to +185 
Compliance 
– 
EU  RoHS  6/6,  IEC/EN  60728-11,  IEC/EN  60065,  EN60825-1:2007,  EN 
50083-2,  FCC  Part  76,  Subpark  K,  CB  Scheme  Certification  w/All 
National Deviation & CENELEC Common Mods