An EVB protocol timer in 802.1Q-2014 standard is expressed as a timer exponent whose definition is a value between 
0 and 31, representing a positive integer for the exponent of 2, which forms the multiplier of 10 microseconds to give 
the timer value. For example, a value of 4 means the associate timer value equals 2^4 x 10 μs, or 160 μs.  
The table below indicates some default exponent values used on DFA leaf switches and the Nexus 1000V switch: 
Exponent value 
Approximate timer value 
14 (default ECP retransmission value) 
163 milliseconds 
20 (default keepalive value on Nexus1000V 
switch) 
10 seconds 
25 (default resource-wait value on leaf 
switch) 
335 seconds 
27 (default keepalive value on leaf switch) 
22 minutes 
 
3.5  VDP Profile Instantiation (High-level overview) 
 
 
 
 
 
 
 
 
 
 
 
 
The major steps involved in the segment-based profile instantiation are: 
An association request is made for a given segment. 
If the segment’s configuration has not yet been instantiated, the HMM process retrieves the necessary infor-
mation from the LDAP database via ADBM process. 
In parallel, the HMM requests a free dynamic VLAN from the VLAN manager process 
When profile contents and parameters are available, the HMM process requests the port-profile process to 
apply the parametrized configuration.  
ADBM/LDAP
 
HMM
 
PPM/VSH
 
EVB
 
1/ Notify of a new segment  
 ID – Send a new segment ID notification  
Vlan Mgr
 
2a/ Retrieve network and tenant 
profile content parameters 
2b/ Request a free dynamic VLAN 
and map it to the segment ID 
3/ Apply configuration