2.3.1  Do a manual pull of the profile/instance and verify it can get applied 
Below is a working case of a manual (i.e. not triggered by traffic or VDP, but by the user through CLI) pull that instanti-
ates vlan 112 on port-channel interface 104 (an interface part of mobility domain PineForest):
   
acorn1%PineForest:Tree1# fabric database auto-pull dot1q 112 interface port-channel 104 
acorn1%PineForest:Tree1# show fabric database host statistics  
ADBM Requests                  2               
ADBM Responses                 2               
Profile Apply Received         1               
Profile vPC Queued             0               
Profile Local Apply Queued     0               
Profile Local UnApply Queued   0               
Profile Apply Sent             1               
Profile Apply Responses        5               
Profile Apply Success          1               
Profile Commands               4               
Profile High Queue adds        1               
Outstanding vlan requests      0               
Outstanding adbm requests      0               
Outstanding Profile Applies                  
Outstanding vPC Profile Applies 0               
 
acorn1%PineForest:Tree1# show fabric database host dot1q 112  
instance_index 0 
Got Local originated vlan type trigger at 16:48:52  
Number of associated interfaces: 1  
Sent to Database Manager at 16:48:53  
Received Parameters from Database Manager at 16:48:53  
Sent to vPC peer at 16:48:54  
Completed executing all commands on vPC peer at 16:48:54  
Displaying Data Snooping Ports 
Interface      Encap      Flags State