Cisco Cisco 1 GHz GainStar Node Installation Guide

Page of 93
3-14 
Balancing and Setup 
    4035009 Rev B 
Setting OMI for Reverse Path Transmitter 
To Set Up the OMI for Reverse Path Transmitter 
Follow these steps to setup OMI for the reverse path transmitter. See below. 
 
Consult the system design print to find proper OMI levels. 
When the GainStar Mini Node is powered on, the green LED will light. 
Insert the test probe into the test probe as above position. 
Test the signal level at the maximum frequency of reverse path. 
When the measured level is 20 dBmV, the corresponding OMI of the reverse 
transmitter is 10%, OMI can be changed by adjusting the reverse output PAD. See 
the chart below. 
 
Remove the test probe from the test point. 
 
 
dBmV