Cisco Cisco 1 GHz GainStar Node Installation Guide

Page of 92
 
Chapter 2        Installation and Configuration 
 
 
 
10 
OL-31947-02 
Before You Begin 
The procedures in this chapter assume that you have completed the following: 
 
Prepared the installation site 
 
Located the coaxial cable, with or without the pin-type coaxial connectors 
mounted on the cable 
 
Required Tools 
Before you start, make sure that you have the following tools: 
 
Torque wrench with a 1/2-inch socket 
 
Flat-blade screwdriver 
 
Heavy-duty wire cutters or snips 
 
Torque wrench set 
 
Torque Specifications 
The following table lists the torque specifications for the GainStar Mini Node. 
Fastener 
Torque Specification 
Illustration 
Housing closure bolts   
6.8 Nm to 9.0 Nm   
 
Housing grounding screw 
0.9 Nm to 1.0 Nm 
 
Housing plugs test point port 
plugs   
6.8 Nm to 9.0 Nm   
 
RF PG11 to 5/8” adapter 
12.0 Nm to 16.0 Nm 
 
Strand clamp mounting 
bracket bolts 
6.8 Nm to 9.0 Nm