To Close the Mini Node Housing
Complete the following steps to close the GainStar Mini Node housing.
CAUTION:
Avoid moisture damage and RF leakage! Follow the procedure
exactly as shown below to ensure a proper seal.
exactly as shown below to ensure a proper seal.
1 Make sure that the housing gaskets are clean and in the correct position. Wipe off
any excess dirt and debris.
2 Close the housing.
3 Lightly secure the six ½-inch closure bolts with a hex driver or ratchet.
4 Using a torque wrench, tighten the six closure bolts to 2.8 Nm.
3 Lightly secure the six ½-inch closure bolts with a hex driver or ratchet.
4 Using a torque wrench, tighten the six closure bolts to 2.8 Nm.
Important: Tighten the closure bolts in the correct sequence as specified in
Torquing Sequence.
Torquing Sequence.
5 Using the same pattern, tighten the housing closure bolts from 6.8 Nm to 9.0 Nm.
Torquing Sequence
The following diagram shows the proper torquing sequence for the housing closure
bolts.