Setting OMI for Reverse Path Transmitter 
To Set Up the OMI for Reverse Path Transmitter 
Follow these steps to setup OMI for the reverse path transmitter. 
 
1  Consult the system design print to get the proper OMI levels. 
When the GainStar Mini Node is powered on, the green LED will light. 
2  Insert the test probe into the test point. 
3  Test the signal level at the maximum frequency of the reverse path. 
4  If the measured level is 20 dBmV, the corresponding OMI of the reverse 
transmitter is 10%. OMI can be changed by adjusting the reverse output pad. See 
the chart below. 
 
5  Remove the test probe from the test point.