Cisco Cisco 1 GHz GainStar Node Installation Guide

Page of 92
 
Chapter 4        Troubleshooting 
 
 
 
54 
OL-31947-02 
No Reverse RF Signal 
The reverse RF signal can be measured at the mainboard reverse input test point and 
reverse OMI test points. 
No Reverse RF Signal Troubleshooting Table 
Before you begin troubleshooting for no reverse RF signal, verify that the node is 
receiving the proper reverse RF input signals from the downstream amplifiers at the 
node reverse input ports. 
Important: You cannot balance the amplifier without the proper reverse RF input 
signals. 
Possible Cause 
Solution 
No reverse RF signal at the reverse input 
test point(s). 
 
Verify the connection of the RF Cable 
Connector. 
Verify that the node is receiving the 
proper reverse RF input signals. 
Important: You cannot balance the node 
without the proper reverse RF input 
signals. 
Verify that all the proper accessories, 
pads, EQs, Reverse Amplifier, and signal 
director are firmly installed in the correct 
locations. 
Verify that the factory installed 
accessories are firmly installed in the 
correct locations. 
Replace the reverse amplifier module.